Calculadora de calibre de cable

Calcula diametro, area de seccion y resistencia por calibre AWG. Soporta materiales como cobre y aluminio. Herramienta gratuita para ingenieria.

AWG
IcA�m

Opcional: introduce la carga para verificar ampacidad NEC y caída de tensión del 3%.

A
V
in
mm
kcmil
inA�
mmA�
Ic/kft
Ic/km
V%
AWG

What is a Wire Gauge Calculator?

A wire gauge calculator is a specialized electrical engineering tool that calculates various properties of electrical wires based on their American Wire Gauge (AWG) number. This essential tool helps electrical engineers, electricians, and DIY enthusiasts determine critical wire specifications including diameter, cross-sectional area, and electrical resistance.

The American Wire Gauge (AWG) system is the standard for measuring wire diameter in North America. As the AWG number increases, the wire diameter decreases. For example, AWG 10 wire is thicker than AWG 12 wire. Our calculator handles the complex mathematical conversions between AWG numbers and physical measurements.

How the Wire Gauge Calculator Works

Our calculator uses the standard AWG formulas to convert gauge numbers to physical dimensions and electrical properties. The calculation process involves several key steps:

First, the calculator determines the wire diameter using the AWG formula: d = 0.005 A- 92^((36-AWG)/39) inches. Then it calculates the cross-sectional area using the circular mil formula. Finally, it computes electrical resistance using Ohm's law, accounting for the wire material's resistivity and length.

AWG Formula and Standards

The AWG system is based on a geometric progression where each gauge number represents a specific diameter. The formula ensures that each AWG number has approximately 20.6% less cross-sectional area than the previous number, making it easy to calculate wire properties for electrical applications.

AWG Diameter Formulas

Diameter (inches) = 0.005 × 92((36 - AWG) / 39)

Diameter (mm) = 0.127 × 92((36 - AWG) / 39)

Cross-Sectional Area Formulas

Area (kcmil) = 1000 × diameter² (inches)

Area (in²) =
π4
× diameter² (inches)
Area (mm²) =
π4
× diameter² (mm)

Resistance Formulas

R (Ω/1000ft) =
0.3048×10⁹ × ρ25.4² × Ain²
R (Ω/1000m) =
10⁹ × ρAmm²

Where: ρ = resistivity (Ω·m), A = cross-sectional area

Key Features of Our Wire Gauge Calculator

  • Accurate AWG to diameter conversion (inches and millimeters)
  • Precise cross-sectional area calculation (square inches, square millimeters, kcmil)
  • Electrical resistance calculation per 1000 feet/meters
  • Support for 8 different wire materials (copper, aluminum, silver, gold, etc.)
  • Custom resistivity input for specialized materials
  • Verificación integrada de ampacidad NEC y caída de tensión del 3%
  • Professional-grade accuracy for engineering applications
  • Mobile-friendly responsive design
  • Free to use with no registration required

Supported Wire Materials

Our calculator supports multiple wire materials, each with different electrical properties:

  • Copper (1.72A-10�?��?, IcA�m) - Most common electrical conductor
  • Aluminum (2.82A-10�?��?, IcA�m) - Lightweight alternative to copper
  • Silver (1.59A-10�?��?, IcA�m) - Best conductor, used in specialized applications
  • Gold (2.44A-10�?��?, IcA�m) - Corrosion-resistant, used in electronics
  • Nickel (6.99A-10�?��?, IcA�m) - High-temperature applications
  • Carbon Steel (1.43A-10�?��?� IcA�m) - Structural applications
  • Electrical Steel (4.6A-10�?��?� IcA�m) - Transformer cores
  • Nichrome (1.10A-10�?��? IcA�m) - Heating elements

Professional Applications

  • Electrical engineering and power system design
  • Wire selection for residential and commercial projects
  • Voltage drop calculations in electrical circuits
  • Power distribution planning and load calculations
  • Electronics and circuit board design
  • Electrical code compliance and safety standards
  • Renewable energy system design (solar, wind)
  • Automotive electrical system design
  • Industrial control panel wiring
  • Telecommunications and data center infrastructure
Calculadora de calibre de cable — Calcula diametro, area de seccion y resistencia por calibre AWG. Soporta materiales como cobre y aluminio. Herramienta g
Calculadora de calibre de cable

Common Calculation Examples

Here are some practical examples of how to use our wire gauge calculator:

Example: AWG 12 Copper Wire

Diameter (inches) = 0.005 × 92((36 - 12) / 39) = 0.005 × 92

2439
= 0.005 × 920.615 = 0.0808 inches

Diameter (mm) = 0.127 × 920.615 = 2.053 mm

Area (mm²) =
π4
× 2.053² = 3.31 mm²
Resistance (Ω/1000m) =
10⁹ × 1.72×10⁻⁸3.31
= 5.21 Ω/km

Example: AWG 18 Aluminum Wire

Diameter (inches) = 0.005 × 92((36 - 18) / 39) = 0.005 × 92

1839
= 0.005 × 920.462 = 0.0403 inches

Diameter (mm) = 0.127 × 920.462 = 1.024 mm

Area (mm²) =
π4
× 1.024² = 0.823 mm²
Resistance (Ω/1000m) =
10⁹ × 2.82×10⁻⁸0.823
= 34.2 Ω/km
  • AWG 12 copper wire: 0.0808 inches diameter, 0.0000808 square inches area
  • AWG 10 aluminum wire: 0.1019 inches diameter, 0.0001019 square inches area
  • AWG 14 copper wire resistance: 2.525 ohms per 1000 feet
  • AWG 8 silver wire: 0.1285 inches diameter, 0.0001285 square inches area

Important Safety Considerations

When selecting wire gauge for electrical applications, always consider:

  • Current carrying capacity (ampacity) requirements
  • Voltage drop limitations (typically 3-5% maximum)
  • Temperature derating factors
  • Local electrical codes and regulations
  • Environmental conditions (temperature, moisture, chemicals)
  • Installation method (conduit, direct burial, overhead)
  • Future expansion and load growth
  • Safety margins for overload protection

Tips for Using the Wire Gauge Calculator

  • Always round up to the next larger gauge for safety margins
  • Consider voltage drop for long wire runs
  • Account for temperature derating in hot environments
  • Use the correct wire material for your application
  • Check local electrical codes for minimum requirements
  • Consider future expansion when sizing wires
  • Use proper wire connectors rated for the wire gauge
  • Follow manufacturer specifications for specialized applications

AWG Wire Gauge Chart

Complete reference chart showing AWG wire gauge numbers, diameters, and cross-sectional areas:

AWG #Diameter (inch)Diameter (mm)Area (kcmil)Area (mmA�)
0000 (4/0)0.460011.6840211.6000107.2193
000 (3/0)0.409610.4049167.806485.0288
00 (2/0)0.36489.2658133.076567.4309
0 (1/0)0.32498.2515105.534553.4751
10.28937.348183.692742.4077
20.25766.543766.371333.6308
30.22945.827352.634826.6705
40.20435.189441.741321.1506
50.18194.621333.102416.7732
60.16204.115426.251413.3018
70.14433.664920.818310.5488
80.12853.263616.50928.3656
90.11442.905813.09276.6342
100.10192.588210.38305.2612
110.09072.30388.23414.1723
120.08082.05256.52993.3088
130.07201.82885.17852.6240
140.06411.62814.10682.0809
150.05711.45033.25681.6502
160.05081.29032.58271.3087
170.04531.15062.04821.0378
180.04031.02361.62430.8230
190.03590.91161.28810.6527
200.03200.81281.02150.5176
210.02850.72390.81010.4103
220.02530.64260.64240.3255
230.02260.57400.50950.2581
240.02010.51060.40400.2047
250.01790.45470.32040.1624
260.01590.40390.25410.1288
270.01420.36070.20150.1021
280.01260.32000.15980.0810
290.01130.28700.12670.0642
300.01000.25400.10050.0509
310.00890.22610.07970.0404
320.00800.20320.06320.0320
330.00710.18030.05010.0254
340.00630.16010.03970.0201
350.00560.14220.03150.0160
360.00500.12700.02500.0127
370.00450.11430.01980.0100
380.00400.10160.01570.0080
390.00350.08890.01250.0063
400.00310.07870.00990.0050

Preguntas Frecuentes

Como referencia inicial para cobre a 60°C ambiente bajo condiciones típicas NEC: AWG 14 (2,5 mm²) lleva 15 A, AWG 12 (4 mm²) lleva 20 A, AWG 10 (6 mm²) lleva 30 A, AWG 8 (10 mm²) lleva 40-50 A, AWG 6 (16 mm²) lleva 55-65 A, AWG 4 (25 mm²) lleva 70-85 A, AWG 2 (35 mm²) lleva 95-115 A. Son ampacidades base de la Tabla 310.16 del NEC y deben corregirse por temperatura ambiente superior a 30°C, más de tres conductores activos en una canalización, y cargas continuas (multiplicar por 1,25). Los conductores de aluminio llevan aproximadamente el 78% de la ampacidad del cobre al mismo calibre, así que suba dos pasos AWG. En España y la UE, consulte la ITC-BT-19 del REBT, que tabula la intensidad admisible según el tipo de instalación.

Los tres miden la sección transversal del conductor pero usan diferentes unidades y escalas. AWG (American Wire Gauge) usa una escala numérica contraintuitiva donde números más pequeños significan cables más grandes; los tamaños estándar van de 40 AWG (diminuto) hasta 4/0 AWG (grande). Para conductores por encima de 4/0 AWG, la industria cambia a kcmil (miles de mils circulares). El sistema IEC usado en Europa, Asia y la mayor parte del mundo usa mm² directamente con tamaños preferentes 1,5, 2,5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150 mm². Conversiones rápidas: 1 kcmil = 0,5067 mm²; AWG 12 ≈ 3,31 mm²; AWG 4/0 ≈ 107 mm² ≈ 211 kcmil. España y los países latinoamericanos siguen mayoritariamente la IEC y especifican en mm².

Resistividad (menor es mejor para conductores): plata 1,59, cobre 1,72, oro 2,44, aluminio 2,82, níquel 6,99, acero al carbono 143, nicromo 1100 (todos ×10⁻⁸ Ω·m). El cobre es la referencia práctica: el mejor balance entre conductividad, ductilidad, resistencia a la corrosión y coste. La plata tiene un 8% menos de resistencia pero se oxida y es demasiado cara para conductores en bulk — se usa para chapado RF de alta frecuencia y contactos. El aluminio es 39% más resistivo pero solo el 30% del peso, lo que lo hace dominante para líneas de transmisión aéreas y acometidas grandes. El oro resiste la oxidación y se usa para chapado de conectores donde la fiabilidad importa más que la conductividad. La alta resistencia del nicromo lo hace ideal para resistencias calefactoras.

El número 92 proviene de la proporción geométrica original entre AWG 0000 (0,46 pulgadas de diámetro) y AWG 36 (0,005 pulgadas de diámetro). La proporción es 0,46 / 0,005 = 92, distribuida en 39 pasos de calibre (desde 4/0 = paso −3 hasta 36 = paso 36). Así que cada paso multiplica el diámetro por 92^(1/39) ≈ 1,1229. Esto fue elegido deliberadamente por J.R. Brown en 1857 para que cada 6 pasos redujeran a la mitad el diámetro y cada 3 pasos redujeran a la mitad el área — aritmética útil en una era anterior a las calculadoras. La fórmula d(pulg) = 0,005 × 92^((36 − AWG)/39) es exacta por definición en la ASTM B258, y la equivalente d(mm) = 0,127 × 92^((36 − AWG)/39) resulta de multiplicar por 25,4 mm/pulgada.

Un mil circular (cmil) es el área de un círculo con un diámetro de 0,001 pulgada (1 mil), definido para que el área en cmil sea igual al diámetro en mils al cuadrado — sin necesidad de π. Para un cable de diámetro d mils, área = d² cmil. Esto elimina π de los cálculos eléctricos con conductores redondos, simplificando tablas y documentos históricos. Para conductores grandes por encima de 4/0 AWG, la unidad pasa a kcmil (miles de mils circulares): 250 kcmil = 250.000 cmil ≈ 127 mm². Los tamaños estándar a escala de servicios públicos son 500, 750, 1000 y 1500 kcmil. Para convertir: cmil × 5,067×10⁻⁴ = mm². La unidad persiste en las tablas de ampacidad del NEC y especificaciones de servicios públicos de EE.UU. aunque la mayoría de la ingeniería moderna use mm² directamente.

Siempre satisfaga ambas restricciones — elija el conductor mayor de los dos. Paso uno: determine el calibre mínimo desde las tablas de ampacidad (NEC 310.16 o REBT ITC-BT-19 según la región), incluyendo corrección por temperatura, número de conductores, y carga continua (×1,25). Paso dos: calcule la caída de tensión a plena carga sobre la longitud real de un sentido usando V_caída = 2 × I × L × R/1000 para CA monofásica. Si la caída supera el 3% (recomendación NEC para circuitos derivados, o exigencia ITC-BT-19 para alumbrado), suba uno o dos calibres hasta que sea aceptable. Paso tres: verifique la elección final contra los límites de llenado del tubo y las valoraciones de tamaño de los bornes. Ejemplo real: un circuito de 30 A de 60 m necesita al menos 10 AWG por ampacidad, pero 8 AWG por caída — instale el 8 AWG.

El AWG se refiere solo a la sección transversal del metal conductor, no al diámetro exterior global. Los conductores trenzados tienen pequeños huecos de aire entre los hilos individuales, que aumentan el tamaño exterior del haz. Para un conductor de cobre Clase B trenzado típico, el diámetro exterior es aproximadamente 15-25% mayor que un cable sólido equivalente del mismo AWG. Para 12 AWG: sólido es 2,05 mm de diámetro; 7 hilos es aproximadamente 2,32 mm; 19 hilos es aproximadamente 2,41 mm. Esto importa para cálculos de llenado de tubo (use el diámetro exterior real de las tablas del fabricante), compatibilidad de conectores (algunos terminales están dimensionados solo para trenzado), y radio de curvatura (el trenzado es más flexible). La conductividad eléctrica es idéntica porque la sección de metal es la misma.

Tres temperaturas importan y deben coordinarse: temperatura nominal del aislamiento (60°C, 75°C o 90°C, marcada en la cubierta), temperatura nominal del terminal (la mayoría de los magnetotérmicos y dispositivos están valorados a 60°C para circuitos ≤100 A o 75°C para >100 A según NEC 110.14(C)), y temperatura ambiente en la instalación. El NEC requiere usar la temperatura más baja del conjunto: un cable THHN de 90°C conectado a un terminal de magnetotérmico de 75°C solo puede valorarse en ampacidad en la columna de 75°C de la Tabla 310.16. Esta es una de las reglas más comúnmente pasadas por alto y causa frecuente de citaciones por violación de código. En España, la ITC-BT-19 también establece temperaturas máximas según el tipo de aislamiento (PVC 70°C, XLPE/EPR 90°C).